Operating instructions for galanz cassette air conditioner. Review of Galanz air conditioners: error codes, comparison of wall-mounted models. Instructions for the control panel and Galanz air conditioners

Instructions for the following models:

GIOWI09RK16
GIOW07RG24

Air conditioner Galanz GIOWI09RK1

Table of contents
Disposal
Title of each part
Preparation before starting work
Selecting operating modes

Useful tips
Cleaning your air conditioner
If you think there is a problem
When not to be used for a long time (At the end of the season of use)
Installation location and electrical work
Precautions

Disposal
When creating this model, materials were used that can be sent for recycling. For this reason, it is necessary to check with the territorial authorities on how to dispose of it specifically in your region.

Title of each part
External unit

During operation, outside air enters at the rear and sides (1). After contact with the heat exchanger, it is output on the front side (2).

Indoor unit

Air enters inside on the top side of the housing (1). Area 2 contains indicators and a sensor that receives commands from his remote control. 3 - area where air comes out. When the air conditioner is turned off, it is closed.

Preparation before use
Connect the device to the mains using an outlet of sufficient rating. Grounding must be good.
Don't forget to install batteries in the remote control. Attention! Do not use batteries of different charge levels or types. Rechargeable batteries cannot be used.

Selecting operating modes
Using the remote control, you can turn on and set the desired operating mode. These can be five main modes. In automatic mode, the device will independently maintain the temperature in a given range by connecting either cooling or heating. If you only need to cool or warm, then a separate mode is suitable - heating or cooling. In dehumidification mode, the air conditioner will remove water dissolved in the air almost without cooling it. Therefore, in this mode it is not possible to set the desired temperature. In the “fan” mode, the device simply recirculates air throughout the room.

Add. modes and settings
This model is useful because when working, it is able to supply street air into the room, thereby relieving you of the need to ventilate the room.
The automatic restart system will automatically turn on your air conditioner to operate in the same mode as before the power failure.
Thanks to the timer, you can program the device to turn on/off regardless of people. Moreover, it is possible to both turn it on and off at the desired time. This will allow you to prepare your apartment for when you come home from work or wake up in the morning.
Night mode makes the device operate quieter, which allows you to get a good night's sleep even with the air conditioner running.
Air ionization makes the air in your home cleaner from dust microorganisms.

Useful tips
If you're battling the heat, don't overdo it—the cold is bad for your health and your energy costs will increase.
Keep an eye on the room where the air conditioner is operating - air will escape through open windows and doors, which will make it difficult for the device to operate.
Controlling the direction of the horizontal partition is also important. Warm air must be directed towards the floor, cold air - parallel to it.
The cleanliness of the air filter is also important, as it can put additional stress on the fan.

Cleaning the air conditioner
All actions must be performed with dry hands until you have disconnected the device from the power supply.
Use only reliable support. Not recommended for use hot water, abrasives and gasoline, because you will simply ruin appearance of your product.
All parts of this air conditioner should be dried in the shade.

If you think there is a problem
The situation when the air conditioner resumed its operation on its own after the reappearance of power in the network should not be considered a malfunction - this may be the work of automatic resumption of operation after a shutdown.
If the appliance stops heating/cooling completely, this may be due to a coolant leak. You need to contact service.
Failure to start within 3 minutes after shutdown is normal operation of the frequent start protection.
While heating your home, the device will periodically stop, which is very important for defrosting the outdoor unit. In addition, be patient when turning on this mode - in order not to supply cold air, the device will not start the indoor unit immediately.
While dehumidifying the air, the device should not operate continuously - since its main task is to remove moisture from the air without cooling it, the operation will periodically stop.
Cold air (which comes out of the indoor unit when cooling and the outdoor unit when heating the home) will cause fog to appear in the area of ​​​​contact with ordinary air - this is the norm.
Please remember that during any thermal operation there will be cold components in the air conditioner, on which condensation will constantly appear. Therefore, water may sometimes leak from the outdoor unit.
If you have problems with the remote control, first check if any button is pressed. The batteries must be installed correctly, in good condition, and charged.
If you are unable to cool the room properly, check whether you have selected the correct operating mode. Standard requirements must also be met: close windows and blinds (direct light from the sun will heat the room). Hot weather and a heating device will interfere with the cooling of the air.
If your air conditioner emits an unpleasant odor when operating, then it’s time to check its internal cavity and filters. In addition, odors can be absorbed from the outside (from the wall or carpet).
Crackling sounds are not a sign of problems - plastic expands when heated and will make similar sounds.
As the refrigerant or condensate moves through the pipe system, it will make gurgling sounds.

When you plan to stop using the air conditioner for a while
Wash the outer parts and dry. Dry the indoor unit using the heating mode for 3 hours. Turn off your air conditioner, remove the plug from the power outlet, and remove the batteries from the remote control.
Before reusing, check that both units have unobstructed air inlet/outlet. After connecting the air conditioner to the mains, place the batteries in your remote control.

Installation location
It is not recommended to place the air conditioner in places where it will disturb neighbors with its noise and drops of condensation. Also, it should not be placed near possible sources of flammable gases. Do not install in places where there is hydrogen sulfide, a humid salty climate, or an abundance of machine oil.

Precautions
Due to the power of the appliance, it must be connected directly to an outlet correct power. It is unacceptable to connect it to an extension cord or a low-power outlet. It cannot be used without grounding.
It is prohibited to repair, modify, or change either the air conditioner itself or the power cord yourself.
Do not place heavy, hot objects on either the blocks or the power cord.
Before removing the plug from the socket, turn off the device using the remote control.
Avoid prolonged exposure to cold air for people, animals, and plants.
Do not insert anything into the openings of the air conditioner while it is running, which could cause injury.
If you detect a burning smell, knocking, or strange sounds, stop the device, unplug it and contact a repair specialist.
If your appliance stops heating/cooling, check to see if it is caused by a refrigerant leak.

Air conditioner Galanz GIOW07RG24

Disposal
Since this product was created using high-tech solutions and materials, it cannot be disposed of as regular waste. In order to secure environment It is recommended to contact authorized companies.
Title of each part

Title of each part

External block.

1 - Posterolateral surface - air intake.
2 - Fan inside the external unit.
3 - Air outlet from the external unit.
Make sure that the air inlet and outlet areas are not obstructed by foreign objects.
One thing to keep in mind with this component is that the noise produced during operation may disturb other occupants. Make sure that there is nothing in the installation location that will obstruct air flow. Due to the fact that the external unit body is made of corrosion-resistant steel, it will serve you for many years.

Indoor unit.

1 - Air intake into the indoor unit.
2 - Indicator zone, window for receiving commands from the remote control.
3 - Air outlet from the indoor unit (closed when inactive).
Its body is made of plastic, there are air intake and exhaust zones. It is important to ensure that they are not blocked by foreign objects. There is a window on the front panel for receiving signals from the remote control, which must be at least one meter from the fluorescent lamps.

Remote controller remote control - necessary for full control of all actions that the air conditioner can perform.

1 - Timer activation button.
2 - Display illumination in the dark.
3 - Turn on sleep mode.
4 - Temperature setting buttons - add and reduce.
5 - Fan operating power.
6, 7 - control of additional modes.
8 - selection of the angle of inclination of the horizontal partition.
9 - Select operating mode.
10 - Connecting turbo mode.
11 - Turning the ionizer on and off.
12 - Turning the air conditioner on and off.
13 - Air freshening.
14 - Connecting the plasma filter.

Preparation before starting work

Installation is carried out by certified specialists. Before use, insert the plug into an outlet that is suitable for this device. Grounding must be connected. Install batteries into the remote control. Keep in mind that the batteries must be of the same type, new. Make sure there are no obstructions to air movement around the outdoor and indoor units. Turn on the device by pressing the ON|OFF button.

Selecting operating modes
The following operating modes are available for this air conditioner:
Auto;
Cooling;
Heating;
Air dehumidification;
Fan.
The desired temperature is selected by pressing the up and down buttons on the remote control.
In Auto mode The room temperature is maintained at a given level. When the temperature drops, heating is automatically turned on, and when the temperature exceeds the value you set, cooling is turned on.
Cooling mode more convenient in the hot season. The air conditioner will maintain the temperature no higher than the one you set. At the same time, air dehumidification will occur.
Air drying mode - the device will work to dehumidify the air, but at the same time minimally affecting the temperature. It is impossible to set the desired temperature value in this mode.
Fan mode ensures air circulation in the room.
Heating mode suitable for heating your home.

More information. Due to the fact that the surface of the heat exchanger is characterized by increased wettability, moisture drains faster and leaves the working area. This reduces energy costs. In addition, the heat exchanger tubes are designed to optimize heat transfer, which also helps reduce energy consumption.
There is a cold air protection function. When starting room heating, the fan starts working only when the heat exchanger heats up to a sufficient level.
The autostart function turns on and switches the air conditioner to the same mode in which it was operating before the power outage.
Additional modes and settings
The "Turbo" mode allows you to increase the fan speed at will, which increases the efficiency of cooling or heating the air.
During the cold season, the heating and defrosting function of the heat exchanger will protect your outdoor unit from icing and damage.
To reduce the load on your electrical wiring, a soft start system is provided.
“Timer” function - with its help you can specify the time to turn on (start timer) and time to turn off the air conditioner. This automates and simplifies the use of the device.
There is also a self-diagnosis function that will determine the condition of the air conditioner and possible problems without calling a specialist.
When using the air conditioner, you can activate an additional silent fan mode to reduce discomfort and energy consumption.

Cleaning your air conditioner
To clean the device, unplug it. Choose a stable support for yourself.
Do not use gasoline, thinner, water hotter than 50 degrees Celsius, or abrasive cleaning powders to treat the surface. This can ruin the appearance of the plastic.

If you think there is a problem
The air conditioner doesn't work. Check whether the plug is connected to the power outlet.
The device cannot be turned on 3 minutes after it is turned off. This is normal and is intended to protect against frequent starts.
When heating starts, the indoor unit does not turn on for several minutes. This is a normal phenomenon - until the heat exchanger temperature reaches the desired value, the fan will not start working.
In heating mode, the indoor unit switches off periodically. This is necessary to defrost the external unit. In this mode, the external unit is overcooled, so water freezes on it. To prevent damage to the device, it must be regularly de-iced.
When operating in room heating mode, white smoke comes out of the external unit. In this mode, the external unit releases cold air outside. As a result, a fog begins to form around it, similar in appearance to smoke.
After a power outage, the air conditioner turned on on its own, although no one used the remote control. If before the power outage in the network, the air conditioner was working in one of the modes set from the remote control, then after the power supply appears in the network, it will automatically continue to work in the same mode.
Water flows from the outdoor unit when using the space heating mode. This is normal, since the heat exchanger of the external unit cools down until condensation and ice appear on it.
The remote control does not work or the image on the display fades. It is necessary to check whether the batteries are present, whether they are installed correctly and, if necessary, replace them with new ones.
No heating or cooling of the room. Check whether the operating mode is set correctly. Are there any obstacles to air movement? Isn't it open doors and windows in this room? There may be a decrease in operating efficiency if there are too many people in the room, it is very hot outside, or a heating device is used in the room.
After turning on the heating mode, the device does not turn on immediately. This is normal, the device must warm up to the desired level before turning on the indoor unit.
There is a foreign smell in the air flow coming out of the air conditioner. First of all, you need to check for mold; then the smell may come from objects adjacent to the indoor unit (carpet or wallpaper).
Crackling sounds are heard during operation. This may be normal, as the plastic may expand when heated, which will cause cracking.
Gurgling sounds are heard during operation or when the device is turned off. During operation, the movement of condensate or refrigerant would normally cause such sounds. When the air conditioner is already turned off, water flowing through the hose may cause gurgling noise. Also, check if there is an exhaust fan running, air will be sucked into the room through the condensate hose, causing a gurgling sound.

At the end of the season of use
1. Turn on the air conditioner to heat for about three hours to dry the indoor unit. This will protect against mold.
2. Turn off the device using the remote control.
3. Disconnect the power plug.
4. Remove batteries from the remote control.

To turn on after a long period of inactivity.
1. Check whether there are any obstructions in the air movement of both units (indoor and outdoor).
2. Check the ground connection.
3. Connect the plug to the power supply.
4. Install batteries in the remote control and use the device.

Installation location and electrical work
Please note that the outdoor unit will make noise, which may disturb people nearby.
Do not install the air conditioner in places where oil splashes may occur, in a salty, humid climate, in places with high-frequency electromagnetic equipment, or in places where there is no normal air flow from the outdoor unit.
Installation must be carried out by specialists with special training.

Precautions
Do not connect the plug to an extension cord or carrier as this may cause a fire.
Do not unplug the power plug while the air conditioner is running. First turn it off using your remote control.
It is prohibited to rearrange, repair or modify the air conditioner yourself. This must be done by certified employees.
Do not stand in the path of cold air from the indoor unit - this may cause illness.
Do not insert your fingers or foreign objects into any openings in the air conditioner housing. This is fraught with injury.
If strange things appear in the operation of the air conditioner (burning smell, unusual noise), then you need to call the service staff.
Remember, if the device does not cool or heat, it may be due to a refrigerant leak. In this case, it is recommended to call repair specialists to inspect and diagnose the device.
If you do not intend to use the device for some time, unplug it from the power supply.
Unplug the appliance during a thunderstorm.

The Galanz company was founded back in 1978. Since that moment, the direction of activity has changed several times - production workshops for the production of textiles were repurposed and supplemented with equipment for the production of household and then climate control equipment. The production of air conditioners of various lines was put into production only in 2000. Air conditioners of the De Lux class were actively produced and put on sale. Already in 2003, the largest production complex in China was opened in the city of Zhongshan. Also, since 2005, a research center has been successfully operating to develop new climate control equipment. This allows us to continuously improve product quality, improve and refine existing air conditioner models and work on the production of new high-tech equipment.

Main lines of split systems

Today, several lines of climate control equipment are produced under the Galans brand. This includes both relatively economical (budget) models with a standard set of functions, and expensive split systems with rich functionality, stylish design and increased performance.

Galanz inverter split systems are suitable for installation within an apartment, house or office. Also, the operation of powerful models is acceptable in rooms with a large area: cafes or restaurants.

The device consists of several blocks and functional elements:

  • an external unit (mounted outside the room), where the compressor is located;
  • indoor unit made in a designer style - placement directly in the room;
  • pipes;
  • electrical wires;
  • remote control mechanism.

The external unit does most of the work of cooling or warming the air flow. It is equipped with a fan, devices for removing condensate and hot air. Internal is required for air intake from the room and evaporation. It is located directly indoors and has stylish design. Internal and external blocks connected to each other by wires and pipes. Control and setting of parameters are carried out remotely. To do this, use the remote control for the air conditioner of the selected model.

The air conditioner is installed according to standard scheme, only by experienced specialists. Preliminary determination of block placement locations is required. Depending on the model, the galanz split system can perform the following functions:

  • heating in cool weather (not lower than the temperature indicated in the instructions);
  • air cooling;
  • removing excess moisture from the air;
  • moisturizing until certain indicators are achieved;
  • purifying the air from dust particles;
  • removal of odors;
  • air aromatization;
  • ionization;
  • airflow without heating or cooling.

The system can be controlled remotely using the remote control. The device operates automatically, maintaining a favorable microclimate in the room. Most split systems, such as the Galantz Galaxy air conditioner, can be turned off using a timer and have a self-diagnosis function for faults. By adjusting the position of the flaps, you can change the direction of air flow, and also use the system as a fan.

Comparison of characteristics of popular models

Instructions for the control panel and Galanz air conditioners

Modern split systems are controlled remotely. In order to turn on the galaxy air conditioner or select the appropriate mode, it is not at all necessary to approach the location of the indoor unit. You just need to use a remote control that has the range specified in the manual.

Using the remote control you can perform the following actions:

  • enable or disable the split system;
  • configure the operating mode;
  • adjust automatically maintained temperature indicators;
  • set a timer;
  • enable additional features.


The remote control for the air conditioner is usually included in the basic kit and there is no need to purchase it separately. Application according to the information provided in the instructions. If you have questions regarding device control, you can further study photo or video reviews.

Using the remote control makes the process of operating the split system even simpler and more convenient. To change the mode, there is no need to be distracted from your usual activities or work - the range of the remote device is quite large. For proper operation, you must monitor the battery charge level shown on the display. The display can also notify you of malfunctions or breakdowns, since it is the error code that is displayed on it.

Error codes for Galanz air conditioners

Galanz air conditioner instructions clearly describe all the requirements for operating the model. Here the conditions necessary for full operation and the limits of permissible temperatures are indicated: at sharply negative temperatures (the limits are indicated in the induction of a specific model), split systems are not recommended for heating. The air will be heated in increased mode, which will lead to overload of the system and its failure. This is why it is so important to study the technical specifications devices.

Some common breakdowns that require immediate air conditioner repair include:

  • relay failure;
  • clogging of the drainage system;
  • insufficient refrigerant filling, shortage or excess;
  • no refrigerant entering the evaporator;
  • compressor jammed;
  • violation in the starting board;
  • thermostat failure.


It is not always the case that a malfunction requires repair and delivery of the air conditioner to service center. Often it is enough to just get things working by replacing the filter or batteries in the remote control. The problem may lie in insufficient energy supply. There may have been errors made during the installation process. The main thing is to correctly determine the cause of the malfunction and eliminate it as soon as possible.

You can find out the exact cause of the breakdown and understand what exactly is wrong with the air conditioner by paying attention to the electronic inscription on the display. Majority modern models have a self-diagnosis function for faults. If the device supports this function, a code will appear on the display. Each individual code corresponds to a specific malfunction. The code method is very convenient. It allows you to avoid lengthy diagnostics and delivery of the device to a service center, which would take a lot of time. Air conditioner error codes are a simple and quick way to inform a technician about the need for a certain type of repair work. So modern way diagnostics (system self-diagnosis) reduces time and financial costs. However, this does not mean that the user will be able to solve the problem on his own without the participation of a professional. If you see a specific set of characters displayed on the electronic display, you must contact the service center.

The instructions for the air conditioner control panel are divided into chapters that describe in detail the functions and rules of use.

All air conditioner control panels are divided into infrared and wired. The latter type is used for industrial and semi-industrial installations. They transmit signals through thin special wires. One wired remote control controls 3 to 8 air conditioners. How to set up the air conditioner remote control is described in detail in the instructions.

Infrared remote controls work optimally at a distance of up to 4 meters.

At a distance of 4 to 8 meters, bright lighting may disrupt the infrared beam.

The instructions for the air conditioner control panel begin with a schematic representation of the device indicating its parts and buttons.

Basic functions

The description of the air conditioner remote control says: to exit to the main functions menu, you need to press the MODE button. The display shows the following modes:

  • HEAT– the air heats up to 30 degrees;
  • COOL– the air is cooled to +15 – 18 degrees. To change the temperature, you need to press the down or up arrows;
  • DRY– air dehumidification. With a stable temperature, humidity decreases;
  • FAN– regulates the fan rotation speed. Typically 3 speeds are set;
  • AUTO– all parameters are set automatically. Sometimes this mode is activated with a separate button. It can also be started from the air conditioner body, without a remote control;
  • SLEEP– quiet operation at night;
  • SWING– a special mode of intensive ventilation of the room.

Rules for replacing batteries

In the description of the air conditioner remote control, a separate section is devoted correct use devices:

  • You need to change both batteries at once and install the same ones. To ensure that the remote control settings are not lost, replacement should be carried out as quickly as possible;
  • During a long period of inactivity, it is advisable to remove the batteries from the remote control;
  • With standard use, batteries last about 12 months. Some models indicate that the batteries need to be replaced. The fact that the batteries are weak is noticeable by the dimming of the display brightness and slow response to commands;
  • Do not attempt to recharge disposable batteries.

Remote control

  • In order for the signal from the remote control to reach the receiving device, it is necessary to point the LED at the air conditioner. Any physical obstacles interfere with the passage of the signal. Setting up the air conditioner remote control, as the instructions indicate, is not at all difficult;
  • The remote control should be protected from falls and getting wet;
  • The remote control operates at a distance of no more than 8 meters;
  • If dust accumulates on the LED, it also interferes with the passage of the infrared beam. Therefore, the remote control must be wiped periodically with a dry cloth.

The same and consists of entering the required code into the remote control memory. As a rule, the remote control is supplied with codes for different models air conditioners. There are two modes for setting up the remote control - automatic and manual.



You can use the automatic mode if you do not know what air conditioner you have or your model is not in the code table. To configure in auto search mode, you need to take the remote control in your hand and point it at the air conditioner. Find the “SELECT” button on the remote control, press and hold it for 5 seconds, then release.



The remote control will automatically send commands to the air conditioner and go through all available codes. In this case, the codes on the remote control display will flash and change. Once the correct code appears, you will hear a beep from your device and the air conditioner will turn on. At this moment, you must press any button on the remote control; the code scanning process will be stopped.


Check the operation of the air conditioner with this code. If the commands are not executed correctly or some functions do not work, run the auto code search again until you find the code under which your air conditioner will work correctly.


Manual setup takes less time. Find the code in the code table for your air conditioner model, there may be several of them. Press the “SELECT” button, and the code on the remote control display should blink once. Using the number buttons, enter the code into the remote control memory and press the “ENTER” button, the remote control is programmed.



Check how the air conditioner executes commands. If the air conditioner is not working correctly, try entering the remaining codes one by one. You can also cycle through the codes using the “TEMP+” and “TEMP-” buttons.



After entering the correct code, the air conditioner control panel is ready for operation. All basic functions will be available to you. From the remote control you can select the operating mode of the air conditioner - cold, heat, ventilation, automatic mode. You can set the desired temperature, adjust the fan speed and choose the direction of air flow.